Parameter |
Model 21.01A |
Model 21.01B |
Model 21.02A |
Model 21.02B |
|
Flow capacity at 21 MPa (3000 psi) |
|
|
|
|
|
At 60 Hz |
58.1 L/min (15 GPM) |
116 L/min (30 GPM) |
232 L/min (60 GPM) |
697 L/min (180 GPM) |
|
At 50 Hz |
48.4 L/min (12 GPM) |
97 L/min (25 GPM) |
193 L/min (50 GPM) |
581 L/min (150 GPM) |
|
Pump Motor |
|
|
|
|
|
Motor Type |
Totally enclosed, fan cooled |
Totally enclosed, fan cooled |
Totally enclosed, fan cooled (2) |
Totally enclosed, fan cooled (3) |
|
Rating |
22.6 kW (30 hp) |
56.5 kW (75 hp) |
56.5 kW (75hp) |
94.25 kW (125 hp) |
|
Operating voltage |
460V 50- |
460V 50- |
460V 50- |
460V 50- |
|
Continuous amps |
34 A |
86 A |
175 A |
431 A |
|
Starter type |
Line voltage std |
Line voltage std |
Line voltage std |
Line voltage std |
|
Solenoid control amps (from local 24 VDC power supply) |
3.2 A |
3.2 A |
3.2 A |
3.2 A |
|
Water requirements |
|
|
|
|
|
Water hose (I.D.) |
12.7 mm (0.5 in) |
19.7 mm (.75 in) |
25.4 mm (1 in) |
50 mm (2 in) |
|
Cooling water flow |
Varies Contact ANCO |
Varies Contact ANCO |
Varies Contact ANCO |
Varies Contact ANCO |
|
Water pressure differential at the heat exchanger |
0.17 MPa (25 psi) |
0.17 MPa (25 psi) |
0.17 MPa (25 psi) |
0.17 MPa (25 psi) |
|
Maximum allowable input water pressure |
0.8 MPa (120 psi) |
0.8 MPa (120 psi) |
0.8 MPa (120 psi) |
0.8 MPa (120 psi) |
|
Maximum cooling water heat load |
17000 kcal/hr (66300 Btu/hr) |
43000 kcal/hr (167000 Btu/hr) |
86000 kcal/hr (335000 Btu/hr) |
210000 kcal/hr (819000 Btu/hr) |
|
Atmospheric heat load1 |
2300 kcal/hr (9000 Btu/hr) |
5800 kcal/hr (22500 Btu/hr)
|
11600 kcal/hr (45000 Btu/hr) |
28000 kcal/hr (110000 Btu/hr) |
|
Maximum ambient operating temperature
|
40 C (104 F) |
40 C (104 F) |
40 C (104 F) |
40 C (104 F) |
|
Minimum ambient operating temperature |
4 C (40 F) |
4 C (40 F) |
4 C (40 F) |
4 C (40 F) |
|
Noise rating, dBA at approx. 1 m (3 ft)2 |
71 |
73 |
74 |
82 |
|
Reservoir capacity |
390 L (100 gal) |
775 L (200 gal) |
1550 L (400 gal) |
2300 L (600 gal) |
|
Hydraulic fluid |
|
|
|
|
|
Standard |
Mobil DTE 25 |
Mobil DTE 25 |
Mobile DTE 25 |
Mobil DTE 25 |
|
Alternate |
Shell Tellus 46 AW |
Shell Tellus 46 AW |
Shell Tellus 46 AW |
Shell Tellus 46 AW |
|
Hydraulic fluid filtration (microns) |
|
|
|
|
|
Nominal |
0.45 |
0.45 |
0.45 |
0.45 |
|
Absolute (Beta3 = 200) |
3.0 |
3.0 |
3.0 |
3.0 |
|
Max. fluid operating temperature |
43 C (110 F) |
43 C (110 F) |
43 C (110 F) |
43 C (110 F) |
|
Hydraulic fluid hose connection |
|
|
|
|
|
Pressure and return (two connections each, 37 deg. flare)3 |
- |
- |
- |
- |
|
Drain (three connections, 37deg. (flare) |
- - - |
- - - |
- - -
|
- - - |
|
Height (without casters) |
1270 mm (50 in) |
1830 mm (72 in) |
1830 mm (72 in)
|
2030 mm (80 in) |
|
Length |
1270 mm (50 in) |
1830 mm (72 in) |
1830 mm (72 in) |
2030 mm (80 in) |
|
Width |
1270 mm (50 in)
|
1830 mm (72 in) |
1830 mm (72 in) |
3050 mm (120 in)
|
|
Weight without fluid (uncrated) |
1800 kg (4000 lb) |
2270 kg (5000 lb) |
3180 kg (7000 lb) |
5680 kg (12500 lb) |